Platform Module 01

AI-Assisted Beam-Segment Candidate Generation

Airato's Auto-Planning module generates initial beam configurations from CT anatomy and learned planning patterns, reducing physicist setup time for standard IMRT treatment sites.

5–7
Beam candidates generated
<90s
Candidate generation time

How the Auto-Planning Engine Works

The Auto-Planning module takes the CT image set, OAR contours, and PTV definition as inputs. Using a convolutional neural network trained on historical IMRT cases, the system identifies anatomical feature patterns and maps them to beam configurations that historically achieved acceptable DVH outcomes.

Output is a set of 5–7 beam-angle candidates with initial fluence maps. These are presented to the physicist as starting points — the physicist selects, refines, or discards any candidates before proceeding to dose optimization.

The system does not make autonomous treatment decisions. Every output requires explicit physicist acceptance before entering the optimization phase.

Diagram illustrating AI beam-segment candidate generation for IMRT auto-planning
Technical Detail

Algorithm Overview

Anatomy-Aware Feature Extraction

CNN processes CT slices to identify PTV geometry, OAR proximity patterns, and body habitus features relevant to beam path selection.

Historical Pattern Matching

Beam angles correlated with historically acceptable DVH outcomes for similar anatomical configurations. Trained on real-world cases reviewed by medical physicists.

Physicist Override at Every Step

All candidate configurations are editable. Beam angles, segment weights, and MLC positions can be manually adjusted before optimization proceeds.

Treatment Sites

Supported IMRT Planning Sites

Auto-Planning has been characterized on standard IMRT treatment sites. Performance varies by site complexity — see dosimetric benchmarks for validation cohort details.

Treatment SiteStandard Beam CountAuto-Planning Status
Prostate7–9 beamsCharacterized
Head & Neck7–9 beamsCharacterized
Lung5–7 beamsCharacterized
Cervix5–7 beamsIn evaluation
Rectum5–7 beamsIn evaluation

Dose Optimization

DVH-constraint solver for multi-criteria OAR sparing and target coverage. Works with Auto-Planning output or manual beam configurations.

Learn more

Adaptive RT

Daily re-planning module for anatomy-adaptive treatment delivery. Integrates with the same plan generated by Auto-Planning.

Learn more

Clinical Evidence

Dosimetric benchmarks and validation data for Auto-Planning's beam configuration performance across characterized treatment sites.

View benchmarks

See Auto-Planning with a representative case.

Our clinical team can walk through a prostate or head-and-neck case demonstrating the full candidate generation cycle.

Request Clinical Demo