Clinical Workflow
End-to-End IMRT Planning Workflow
From CT simulation through contouring, AI-assisted planning, physicist review, and final treatment approval — Airato fits directly into the standard radiation therapy workflow without replacing existing steps or personnel.
Full Treatment Planning Cycle
Airato enters at Step 3 (AI Auto-Planning) and exits with a physicist-reviewed plan ready for approval. All prior and subsequent steps are unchanged.
CT Simulation
Patient positioned and immobilized. Simulation CT acquired with appropriate field of view for treatment site. External reference marks placed. CT transferred to TPS workstation via DICOM.
Contouring
Radiation oncologist defines GTV, CTV, PTV margins. Medical physicist or dosimetrist contours OARs. Structure set exported as DICOM RT Structure Set.
AI Auto-Planning (Airato)
CT and structure set received by Airato. Beam candidates generated and dose optimization performed. DVH constraint satisfaction reviewed within Airato. Optimized plan and dose distribution available for physicist review.
Airato stepPhysicist Review
Medical physicist reviews Airato's output: beam configuration, DVH curves, isodose distribution, and OAR constraint satisfaction. Adjustments made as clinically indicated. Physicist approves or rejects plan.
Treatment Approval
Radiation oncologist conducts final clinical review of approved physicist plan. Prescription, DVH objectives, and plan quality confirmed. Plan approved for treatment delivery. DICOM RT Plan exported to linac management system.
The Physicist Workflow with Airato
What Airato Does
- Generates initial beam configuration from CT anatomy
- Optimizes fluence map against DVH constraints
- Displays per-structure constraint satisfaction in real time
- Produces dose distribution for review
What the Physicist Does
- Reviews all Airato-generated beam candidates
- Adjusts beam angles, weights, or MLC positions as needed
- Verifies DVH against institutional constraints
- Signs off on plan quality before oncologist review
- Documents any deviations from AI-generated starting configuration
The Oncologist Workflow with Airato
Faster Plan Availability
Airato reduces physicist setup time, meaning approved plans reach oncologist review earlier in the planning cycle — improving scheduling efficiency for urgent cases.
Consistent Plan Quality
DVH-constraint optimization applied consistently across cases. Oncologist-specified OAR objectives are enforced systematically, reducing variability from manual planning differences.
Unchanged Approval Process
The oncologist's final plan review and approval step is unchanged. Airato output has already been reviewed by the physicist — oncologist sees a fully reviewed plan with DVH documentation.
Walk through a sample clinical case.
Our clinical team can demonstrate the full physicist and oncologist workflow with a representative IMRT case from your treatment site mix.